R175 White Developer for Penetrant and Fluorescent Testing – Fluxo
The successful application of penetrant is completely dependent on the ability of the penetrant to enter a defect which is open to the surface. All paint, organic compounds, oils, greases and any other contaminants must be removed completely before application of the penetrant. Use solvent FLUXO S190.
White Developer for Penetrant and Fluorescent Testing
500 ml Aerosol cans of White Developer for Penetrant and Fluorescent Testing
High Sensibility – High Evaporation Rate
Aspect: White solid particles in a clear liquid
Density (20°C): 0,89
Flash Point: 12°C
Compatible with any metal & many synthetic materials.
Shelf Life: 60 months. Keep the packaging closed after taking out some of the product
Application of Penetrant:
Use FLUXO P125 Red penetrant in ready-to-use – Application by immersion, spraying, brushing, dipping, etc…
Dwell Time:
A 20 minute, or longer, dwell time is mandatory. Contact times are dependent on the component being tested. Dwell time may be shortened down to 10 minutes when only large cracks are sought for, or extended up to several hours for tight cracks. Allow the penetrant to drain from the part.
Removal:
Remove the excess penetrant from the surface, being careful not to remove the penetrant tapped in the defects. Rinse under low pressure (50 to 200 kPa), with the nozzle of gun 30 to 40 cm (12” to 16”) from the part, during the shortest time possible, until the red background disappears. If you can’t or don’t want to use water, remove the excess penetrant with solvent FLUXO S190 or remover FLUXO N130.
Drying:
Begin drying procedure immediately after water wash. Drying temperature of 70°C is normal for oven drying. Use pressurized air to disperse and remove as much excess surface water as possible before placing part in oven.
Developing:
Developers can be applied by spraying or dust storm cabinet. Inspection is normally carried out at least 10 minutes after developing.
Inspection:
Parts shall be inspected as per ISO 3059 standard requirements.